Q: What are the hardware requirements for MSFragger?
A: This depends on the complexity of the search. In general, we recommend at least 16 GB, but complex closed searches and open searches will require more. Additional variable modifications, semi-enzymatic, and non-enzymatic/non-specific searches will require additional memory and processing cores to maintain very short search times. (We do not recommend performing an open search with non-specific cleavage rules.) Performance scales well with the number of processors. Quantification of Bruker timsTOF data will require at least 32 GB.
Q: Does MSFragger require decoys in the FASTA sequence database?
A: Yes, but if you are using MSFragger inside PD-Nodes, please do NOT include decoys. Philosopher/FragPipe can download and format a custom database for you (including the addition of reversed/decoy sequences). See this page for more information about using Philosopher to prepare sequence databases.
Q: Do I need to convert raw MS/MS files to mzML for MSFragger searches?
A: MSFragger/Philosopher can analyze Thermo .raw files, but mzML files are required for TMT/iTRAQ quantification (see this Thermo .raw -> .mzML conversion tutorial). Searching and label-free quantification of Bruker timsTOF data can be done through FragPipe. Complete workflow compatibility information is shown below.
| Thermo/Sciex .mzML | Thermo .raw | Bruker .d | |
|---|---|---|---|
| MSFragger search | ✔ | ✔ | ✔ |
| Label-free quantification | ✔ | ✔ | ✔ |
| TMT/iTRAQ quantification | ✔ | ||
| Crystal-C | ✔ | ✔ | |
| PTMShepherd | ✔ | ✔ | ✔ |
| Spectral library generation | ✔ | ✔ |
Q: How can I analyze TMT-labeled data with MSFragger/Philosopher/FragPipe?
A: We currently support TMT 6, 10, 11, and 16-plex, and iTRAQ 4 and 8-plex quantification from the mzML file format. Workflows for each are available in FragPipe. For command line use, see this Philosopher tutorial for a step-by-step example of TMT searching and quantification. The high-throughput Philosopher pipeline function can also be used for large-scale isobaric labeling experiments.
Q: Can I use MSFragger results with Skyline?
A: MSFragger search results from both Thermo Orbitrap data and Bruker TIMS-TOF data can be used with Skyline.
See this tutorial on importing validated TIMS-TOF PASEF results into Skyline. Similar steps can be followed to import MSFragger results from Thermo data, see the Skyline documentation for more information.
Q: I got a memory error when I tried to run MSFragger. What can I do?
A: First make sure a 64-bit (x64) version of Java runtime environment is installed. (The latest version of JRE, which is 64-bit, can be downloaded here.) If you’re using MSFragger in the command line, make sure to specify the appropriate amount of memory given your hardware configuration (e.g. -Xmx32G to use 32 GB). The database splitting option (available in FragPipe) can be used to reduce the size of the in-memory fragment ion index that MSFragger generates. If you still run out of memory, you can reduce the size of the fragment ion index a few ways, 1) use only reviewed sequences in your fasta database, 2) decrease digest_max_length, 3) remove some variable modifications, 4) try a fully-enzymatic search.
Q: What is the difference between "precursor_mass_lower/upper" and "precursor_true_tolerance"?
A: The precursor_mass_lower/upper parameters are the precursor mass boundaries used in search. For example, precursor_mass_lower = -20, precursor_mass_upper = 20, precursor_mass_units = 1 would result in 20 ppm precursor mass tolerance. On the other hand, precursor_mass_lower = -150, precursor_mass_upper = 500, precursor_mass_units = 0 would be an open search with [-150, +500] Da precursor mass window.
The precursor_true_tolerance is used to break ties in open searches and is also used as precursor_mass_lower/upper in the first search (if applicable). For example, if precursor_true_tolerance = 20, precursor_true_units = 1, MSFragger would use precursor_mass_lower = -20, precursor_mass_upper = 20, precursor_mass_units = 1 in the first search no matter what the precursor_mass_lower/upper values were.
Q: Can low resolution (e.g. ion trap) MS/MS data be used in MSFragger?
A: Low resolution MS/MS spectra are suitable for closed searches, but we recommend open searches only be performed on high mass accuracy MS/MS spectra (e.g acquired in an Orbitrap or high-res TOF).
Q: How should experiments with multiple fractions or experimental groups be handled in FragPipe?
A: See this section of the FragPipe tutorial.
Q: Why do I see 'WARNING: cannot open data file' and 'WARNING: CANNOT correct data file' when running PeptideProphet (with FragPipe or command line philosopher)?
A: These warnings are from PeptideProphet and can be ignored.
Q: Why is the reported number of missed cleavages in a peptide different than I expect?
A: PeptideProphet does not consider a cleavage site missed if it is right next to another cleavage site, e.g. the number of missed cleavage sites in the peptide APTTDEDKK would be changed from 1 to 0 by PeptideProphet.
Q: Why can't I see the MSFragger-PD node after the installation?
A: Please check if you (1) have .Net 4.7 or above installed in your computer, (2) need to unblock the file before installation (click here for more details).
Q: I got an error trying to generate a spectral library with EasyPQP. What can I do?
A: Please check that the appropriate 'MS data type' is selected for your LC-MS files on the 'Workflow' tab of FragPipe. Also make sure you have the latest version of EasyPQP by opening Anaconda Prompt and running these two commands:
pip uninstall --yes easypqp
pip install git+https://github.com/grosenberger/easypqp.git@master
Q: I got an error when trying to update FragPipe. How can I update the tools manually?
A: If GitHub cannot be reached by FragPipe (due to a firewall or some other restriction), you can install the update manually by following these steps:
- Go to: https://github.com/Nesvilab/FragPipe/tree/updates/MSFragger-GUI/updates.
- Download zip files there, save it to the root folder of your FragPipe install.
- Unpack the zip (using extract here option of your archiver, so that it maintains the folder structure).
- You should now have
<FP-install>/tools/xxx.jarfile. - Run FragPipe as you would normally, it should now be updated.