Description

@fraricci

Hi there!

When using a (HSE)BandStructureMaker I noticed that the NSCF calculations (bands and dos) does not have the MAGMOM in the INCAR and I get the following warning in the OUTCAR:

|   You use a magnetic or noncollinear calculation, but did not specify
|   the initial magnetic moment with the MAGMOM tag. Note that a
|   default of 1 will be used for all atoms. This ferromagnetic setup
|   may break the symmetry of the crystal, in particular it may rule
|   out finding an antiferromagnetic solution. Thence, we recommend
|   setting the initial magnetic moment manually or verifying carefully
|   that this magnetic setup is desired.

And results, i.e. the DOS, are quite different between the cases with and without keeping the MAGMOM.

Now, looking at the VASP wiki https://www.vasp.at/wiki/MAGMOM I see the following:
"When restarting a magnetic calculation, MAGMOM is only used to determine the symmetry of the system and not to set the on-site magnetic moment. Therefore, if you remove the MAGMOM tag before restarting from a converged WAVECAR or CHGCAR, the magnetization is likely to be symmetrized away."

So, I suppose that MAGMOM should remain in the INCAR of a NSCF calculations from the previous static one.

I think the lines that remove the MAGMOM are

updates["MAGMOM"] = None

updates["MAGMOM"] = None

What seems odd is that those lines seem to be added a long time ago and nobody complained.
Could this warning be added in recent versions of VASP? I'm using the 6.4.2.

Let me know what you think.