managed-upgrade-operator Metrics (MUO)

The Managed Upgrade Operator reports the following metrics via direct instrumention:

Metrics use to alert SRE

  • upgradeoperator_upgradeconfig_validation_failed: If failed to validate the upgrade config value > 0
  • upgradeoperator_healthcheck_failed: If failed on the cluster health check step value > 0
  • upgradeoperator_scaling_failed: If failed to scale up extra workers value > 0
  • upgradeoperator_controlplane_timeout: If control plane upgrade timeout value > 0
  • upgradeoperator_worker_timeout: If worker nodes upgrade timeout value > 0
  • upgradeoperator_node_drain_timeout: If node cannot be drained successfully in time value > 0
  • upgradeoperator_upgradeconfig_sync_timestamp: Set a timestamp as the value of the metric if the upgradeconfig sync succeeded
  • upgradeoperator_upgrade_started_timestamp: Set a timestamp as the value of the metric when the upgrade commenced
  • upgradeoperator_upgrade_completed_timestamp: Set a timestamp as the value of the metric when the upgrade finished
  • upgradeoperator_controlplane_upgrade_started_timestamp: Set a timestamp as the value of the metric when the controlplane upgrade commenced
  • upgradeoperator_controlplane_upgrade_completed_timestamp: Set a timestamp as the value of the metric when the the controlplane upgrade finished
  • upgradeoperator_workernode_upgrade_started_timestamp: Set a timestamp as the value of the metric when the workerpool upgrade commenced
  • upgradeoperator_workernode_upgrade_completed_timestamp: Set a timestamp as the value of the metric when the workerpool upgrade finished

Metrics for fleet-wide monitoring

The following metrics are forwarded to Observatorium-MST for fleetwide monitoring via grafana

  • upgradeoperator_upgrade_result: Contains results from the previous upgrade. If upgrade fired a paging alert value == 0 and the alerts field contains the name of alerts fired
  • upgradeoperator_healthcheck_failed: Contains preflight health check results from the previous upgrade. If upgrade preflight health check success value == 0 otherwise value == 1. The state field contains in which upgrade state the PHC is performed. The reason field indicates which type of health check is performed.

The following metrics are forwarded to Observatorium-MST on the management clusters for fleetwide monitoring via telemetry

  • upgradeoperator_upgrade_started_timestamp: Set a timestamp as the value of the metric when the upgrade commenced
  • upgradeoperator_upgrade_completed_timestamp: Set a timestamp as the value of the metric when the upgrade finished
  • upgradeoperator_controlplane_upgrade_started_timestamp: Set a timestamp as the value of the metric when the controlplane upgrade commenced
  • upgradeoperator_controlplane_upgrade_completed_timestamp: Set a timestamp as the value of the metric when the the controlplane upgrade finished
  • upgradeoperator_workernode_upgrade_started_timestamp: Set a timestamp as the value of the metric when the workerpool upgrade commenced
  • upgradeoperator_workernode_upgrade_completed_timestamp: Set a timestamp as the value of the metric when the workerpool upgrade finished

How to expose the metric to RHOBS for fleet-wide monitoring

The metrics defined in MUO only live inside the container. Each metric that needs to be sent to RHOBS via remoteWrite should be combined with the sre:telemetry:managed_labels. Details could be found in doc. Follow the steps below to set up the rule to expose metric to RHOBS.

Metrics for upgrade conditions and state

There is now a Collector that creates metrics strictly based on the UpgradeConfig CR.

# HELP managed_upgrade_condition_capacity_added_timestamp Unix Timestamp indicating time of additional compute added
# TYPE managed_upgrade_condition_capacity_added_timestamp gauge
managed_upgrade_condition_capacity_added_timestamp

# HELP managed_upgrade_condition_capacity_removed_timestamp Unix Timestamp indicating time of addtional compute removed
# TYPE managed_upgrade_condition_capacity_removed_timestamp gauge
managed_upgrade_condition_capacity_removed_timestamp

# HELP managed_upgrade_condition_control_plane_completion_timestamp Unix Timestamp indicating completion of upgrade upgrade
# TYPE managed_upgrade_condition_control_plane_completion_timestamp gauge
managed_upgrade_condition_control_plane_completion_timestamp

# HELP managed_upgrade_condition_control_plane_maint_start_timestamp Unix Timestamp indicating start time of control plane maintenance
# TYPE managed_upgrade_condition_control_plane_maint_start_timestamp gauge
managed_upgrade_condition_control_plane_maint_start_timestamp

# HELP managed_upgrade_condition_control_plane_removed_start_timestamp Unix Timestamp indicating removal of control plane maintenance window
# TYPE managed_upgrade_condition_control_plane_removed_start_timestamp gauge
managed_upgrade_condition_control_plane_maint_removed_timestamp

# HELP managed_upgrade_condition_control_plane_upgrade_start_timestamp Unix Timestamp indicating start time of upgrade
# TYPE managed_upgrade_condition_control_plane_upgrade_start_timestamp gauge
managed_upgrade_condition_control_plane_upgrade_start_timestamp

# HELP managed_upgrade_condition_control_plane_upgrade_completion_timestamp Unix Timestamp indicating completion of upgrade
# TYPE managed_upgrade_condition_control_plane_upgrade_completion_timestamp gauge
managed_upgrade_condition_control_plane_upgrade_completion_timestamp

# HELP managed_upgrade_condition_external_dep_check_timestamp Unix Timestamp indicating time of cluster health check
# TYPE managed_upgrade_condition_external_dep_check_timestamp gauge
managed_upgrade_condition_external_dep_check_timestamp

# HELP managed_upgrade_condition_health_check_timestamp Unix Timestamp indicating time of cluster health check
# TYPE managed_upgrade_condition_health_check_timestamp gauge
managed_upgrade_condition_health_check_timestamp

# HELP managed_upgrade_condition_notification_start_timestamp Unix Timestamp indicating time of start upgrade notification event
# TYPE managed_upgrade_condition_notification_start_timestamp gauge
managed_upgrade_condition_notification_start_timestamp

# HELP managed_upgrade_condition_notification_complete_timestamp Unix Timestamp indicating time of complete upgrade notification event
# TYPE managed_upgrade_condition_notification_complete_timestamp gauge
managed_upgrade_condition_notification_complete_timestamp

# HELP managed_upgrade_upgrade_pdb_timeout_minutes Int indicating when the value of PDB timeout in minutes
# TYPE managed_upgrade_upgrade_pdb_timeout_minutes gauge
managed_upgrade_upgrade_pdb_timeout_minutes

# HELP managed_upgrade_upgrade_scheduled Unix Timestamp indicating when the upgrade will execute
# TYPE managed_upgrade_upgrade_scheduled gauge
managed_upgrade_upgrade_scheduled

# HELP managed_upgrade_upgrade_start_timestamp Timestamp of when an upgrade starts
# TYPE managed_upgrade_upgrade_start_timestamp gauge
managed_upgrade_upgrade_start_timestamp

# HELP managed_upgrade_upgrade_complete_timestamp Timestamp of when an upgrade completes entirely
# TYPE managed_upgrade_upgrade_complete_timestamp gauge
managed_upgrade_upgrade_complete_timestamp

# HELP managed_upgrade_condition_workers_maint_start_timestamp Unix Timestamp indicating end of workers maintenace
# TYPE managed_upgrade_condition_workers_maint_start_timestamp gauge
managed_upgrade_condition_workers_maint_start_timestamp

# HELP managed_upgrade_condition_workers_maint_removed_timestamp Unix Timestamp indicating end of workers maintenace
# TYPE managed_upgrade_condition_workers_maint_removed_timestamp gauge
managed_upgrade_condition_workers_maint_removed_timestamp

# HELP managed_upgrade_condition_workers_upgraded_timestamp Unix Timestamp indicating all worker nodes have upgraded
# TYPE managed_upgrade_condition_workers_upgraded_timestamp gauge
managed_upgrade_condition_workers_upgraded_timestamp

# HELP managed_upgrade_condition_post_upgrade_healthcheck_timestamp Unix Timestamp indicating time of post cluster health check
# TYPE managed_upgrade_condition_post_upgrade_healthcheck_timestamp gauge
managed_upgrade_condition_post_upgrade_healthcheck_timestamp