Skip to content

RichardObi/frd-score

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

84 Commits
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

NEWS 1/9/26: 🎉 the FRD paper has been accepted to Medical Image Analysis 🎉!

FRD (Fréchet Radiomic Distance): A Metric Designed for Medical Image Distribution Comparison in the Age of Deep Learning

arXiv paper link: arXiv Paper

frd overview

We recently released an updated and improved version (v1.0) of FRD in our recent paper. The two versions' code repositories can be found below:

FRD Version Reference Path in Repo Availability as PyPi library Proposed in
v1 (v1.0) frd_v1 implementation in progress; update in PyPi to v1.0 will be available soon. Fréchet Radiomic Distance (FRD): A Versatile Metric for Comparing Medical Imaging Datasets
v0 (v0.2) frd_v0 pypi v0.2 Towards Learning Contrast Kinetics with Multi-Condition Latent Diffusion Models

Abstract

Determining whether two sets of images belong to the same or different distributions or domains is a crucial task in modern medical image analysis and deep learning; for example, to evaluate the output quality of image generative models. Currently, metrics used for this task either rely on the (potentially biased) choice of some downstream task, such as segmentation, or adopt task-independent perceptual metrics (e.g., Fréchet Inception Distance/FID) from natural imaging, which we show insufficiently capture anatomical features. To this end, we introduce a new perceptual metric tailored for medical images, FRD (Fréchet Radiomic Distance), which utilizes standardized, clinically meaningful, and interpretable image features. We show that FRD is superior to other image distribution metrics for a range of medical imaging applications, including out-of-domain (OOD) detection, the evaluation of image-to-image translation (by correlating more with downstream task performance as well as anatomical consistency and realism), and the evaluation of unconditional image generation. Moreover, FRD offers additional benefits such as stability and computational efficiency at low sample sizes, sensitivity to image corruptions and adversarial attacks, feature interpretability, and correlation with radiologist-perceived image quality. Additionally, we address key gaps in the literature by presenting an extensive framework for the multifaceted evaluation of image similarity metrics in medical imaging -- including the first large-scale comparative study of generative models for medical image translation -- and release an accessible codebase to facilitate future research. Our results are supported by thorough experiments spanning a variety of datasets, modalities, and downstream tasks, highlighting the broad potential of FRD for medical image analysis.

Citation

Please cite our journal article if you use our code or reference our work:

@article{konzosuala_frd2026,
  title         = {Fr\'echet Radiomic Distance (FRD): A Versatile Metric for Comparing Medical Imaging Datasets},
  author        = {Nicholas Konz* and Richard Osuala* and Preeti Verma and Yuwen Chen and Hanxue Gu and Haoyu Dong and Yaqian Chen and Andrew Marshall and Lidia Garrucho and Kaisar Kushibar and Daniel M. Lang and Gene S. Kim and Lars J. Grimm and John M. Lewin and James S. Duncan and Julia A. Schnabel and Oliver Diaz and Karim Lekadir and Maciej A. Mazurowski},
  year          = {2026},
  journal={Medical Image Analysis},
  pages={103943},
  publisher={Elsevier}
}