Skip to content
Ken Sharp edited this page Dec 10, 2025 · 2 revisions

Servo Open

Initialize one or more servos.

LabVIEW

Command Packet

Servo Open
Description Initialize one or more servos.
Size Variable
Format 0 1 2 3 4 5 6 7
7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
SoF : 0xFF PACKET SIZE PACKET NUM CMD : 0x0140 ~CHANNELS CHECKSUM
SoF Start of Frame. Always 0xFF.
PACKET SIZE Packet Size In Bytes
PACKET NUM The Current Packet Number. This value increments with each new packet.
CMD Servo Open Command.
~CHANNELS Servo Channel(s). Each channel is represented with one byte.
CHECKSUM Checksum. Computed by adding all of the bytes in the packet in U8 form ignoring rollover.

LINX Target

Developer Note

It's likely that this will allocate memory on the device.

Response Packet

Servo Open Response
Description LINX device's response to Servo Open command
Size 6 Bytes
Format 0 1 2 3 4 5
7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
SoF : 0xFF PACKET SIZE PACKET NUM STATUS CHECKSUM
SoF Start of Frame. Always 0xFF.
PACKET SIZE Total packet size in bytes.
PACKET NUM The packet number of the packet that generated the response.
STATUS See Return Status section below.
CHECKSUM Checksum. Computed by adding all of the bytes in the packet in U8 form ignoring rollover.

Return Status

Status Description
0x81 Failed To Allocate Memory For Servo

See Return Status for universal return statuses.

Related Links

LINX

Clone this wiki locally